EW US(02) / Under-sill profile with mesh and foam tape
Add to Wish ListMesh Dimension: 100 mm
Profile Thickness: 1.1 mm
Drip Ledge Height: 8 mm
Dimmensions Of Wings: 21 / 21 mm
Width X Height: 15 x 3 mm
Product description
Under-Sill Profile with Fiberglass Mesh and Foam Tape for ETICS
The Under-Sill Profile is designed to create a flexible, durable connection between the sill and thermal insulation material in ETICS systems.
It combines alkali-resistant PVC, Vertex R 117 fiberglass reinforcement mesh, and double-sided closed-cell PE expansion tape. The profile helps reduce cold and noise penetration, protects the system from weather exposure, and helps prevent hairline cracks at the joint.
Materials:
-
Alkali-resistant PVC
-
Vertex R 117 fiberglass reinforcement mesh
-
Mesh compliant with ETAG 004
-
Double-sided self-adhesive closed-cell PE expansion tape
Features:
-
Suitable for ETICS thermal insulation systems
-
Provides a permanent expansion joint between the sill and insulation material
-
Helps prevent cold penetration
-
Helps reduce noise transmission
-
Protects the system from weather effects
-
Helps prevent hairline cracks at the joint
-
Eliminates the need for additional joint sealing
-
Integrated fiberglass reinforcement mesh
-
Self-adhesive expansion tape for secure sill connection
Installation instructions:
-
Position the under-sill profile at the lower edge of the window or door jamb.
-
Cut a groove in the insulation material according to the profile width and the height of the self-adhesive expansion tape.
-
Fill the prepared groove with adhesive.
-
Apply adhesive to the vertical insulation surface beneath the lower jamb edge.
-
Press the profile into the prepared adhesive bed.
-
Align the profile using a spirit level.
-
Embed the profile’s reinforcement mesh into the adhesive.
-
Remove excess adhesive pressed through the mesh and level it with a metal float.
-
Gradually cover the entire profile mesh with construction adhesive.
-
Reinforce the corners of window and door openings diagonally using fiberglass mesh measuring at least 20 × 30 cm.
-
Allow the adhesive to partially cure.
-
Remove the protective film from the expansion tape.
-
Insert the sill into the building opening.
-
Push the sill toward the window frame, then press it firmly onto the profile’s adhesive tape.
-
Secure the sill to the window frame using screws.