KI 10 / FACADE FIXINGS WITH PLASTIC PIN

Add to Wish List
Koelner
Out of stock
Only %1 left
SKU:
ALLV_KI 10 / FACADE FIXINGS WITH PLASTIC PIN
EAN:
Choose an Option...

Drill Hole Diameter:  10 mm

Disc Diameter:  60 mm

Min Drill Hole Depth Subst A B C:  35 mm

Min Drill Hole Depth Subst D:  50 mm

KI 10 is a hammer-set insulation fixing with a reinforced plastic nail, designed for fastening polystyrene boards, mineral wool, light wood wool building boards, polyurethane boards, wood fibre boards, and lightweight recycled panels in ETICS systems.

Product description

KI 10 / Facade Fixing with Plastic Pin

KI 10 is a hammer-set insulation fixing with a reinforced plastic nail, designed for fastening polystyrene boards, mineral wool, light wood wool building boards, polyurethane boards, wood fibre boards, and lightweight recycled panels in ETICS systems.

Suitable for all substrate categories A, B, C, D, and E, the fixing combines an impact-resistant polypropylene sleeve with a fiberglass-reinforced polyamide nail for fast installation, reliable expansion, and secure fastening. The plastic nail reduces heat transmission to 0.3 W/K, while the point thermal transmittance is 0.003-0.006 W/K.

The specially designed expansion zone allows low embedment depths and reduces drilling requirements. A plate stiffness of 0.4 kN/mm helps create a smooth facade surface and supports a stable insulation system.

Materials:

  • Plug sleeve: impact-resistant polypropylene copolymer PP

  • Nail pin: fiberglass-reinforced polyamide PA 6.0 Nylon

Approved for:

  • Concrete C12/15-C50/60 - use category A

  • Solid brick - use category B

  • Solid sand-lime brick - use category B

  • Hollow sand-lime brick - use category C

  • Hollow lightweight concrete block - use category C

  • Vertically perforated clay block - use category C

  • Lightweight concrete block - use category C

  • Reinforced lightweight aggregate concrete components - use category D

  • Aerated concrete block - use category E

Applications:

  • External Thermal Insulation Composite Systems (ETICS)

  • Polystyrene EPS boards

  • Mineral wool

  • Light wood wool building boards

  • Polyurethane PU boards

  • Wood fibre boards

  • Lightweight recycled panels

Installation:

Drill a hole of the required diameter and depth. Lightly hammer the plastic sleeve through the insulation material into the hole until the required fixing depth is reached. Lightly hammer the plastic nail into the sleeve until the fixing is secure and flush with the insulation surface.

Minimum embedment depth:

  • Masonry: 25 mm

  • Perforated materials: 40 mm

  • Lightweight concrete and aerated concrete: 60 mm

Minimum drilling depth:

  • Masonry: 35 mm

  • Perforated materials: 50 mm

  • Lightweight concrete and aerated concrete: 70 mm

Koelner

Koelner

View more