TSDL-V 8 / Hammer fixing
Add to Wish ListAnchor Drill: 8 mm
Eff Anchor Depth: 30 mm
The TSDL-V hammer fixing is a preassembled fastening system designed for the secure installation of insulation materials in external thermal insulation composite systems (ETICS/WDVS). It consists of an expansion dowel with a holding plate and an expansion nail with a specially designed head.
Product description
Hammer Fixing TSDL-V
The TSDL-V hammer fixing is a preassembled fastening system designed for the secure installation of insulation materials in external thermal insulation composite systems (ETICS/WDVS). It consists of an expansion dowel with a holding plate and an expansion nail with a specially designed head.
Innovations and advantages:
-
Optimally shaped expansion zone provides improved stability in base materials
-
Extended expansion zone ensures a secure hold, even in problematic building materials
-
Modified head design enables flush installation of the dowel plate in the insulation material
-
Sealed special head provides optimal protection against moisture and corrosion while helping prevent heat loss
-
Provides optimal strength values in lengths of up to 300 mm
-
Thermal bridge optimized with a thermal transmission coefficient of 0.002 W/K
Characteristics:
-
Fastening system consisting of an expansion dowel with a holding plate and an expansion nail with a special head
-
Special head reduces unwanted heat loss and provides additional corrosion protection
-
Holding plate features a mortar-gripping surface that is also optimally suited as a plaster carrier
-
Preassembled fastening units reduce installation time and effort
-
European Technical Approval as a multi-use fixing for anchoring bonded thermal insulation composite systems tested according to ETAG 004
-
Meets all requirements for utilization categories A, B, and C
-
Complies with ÖNORM B 6124 and meets all requirements for utilization categories A and B
-
Approved for use with the DSB insulation disc when fastening soft, pressure-resistant, and dimensionally stable insulation materials
Suitability:
Approved under ETA for:
-
Concrete
-
Solid brick
-
Perforated brick
-
Utilization categories A, B, and C
Also suitable for:
-
Natural stone with a dense structure
-
Lightweight concrete solid blocks
-
Lightweight concrete hollow blocks
-
Aerated concrete
Suitable for fastening:
-
Various types of insulation material
-
Insulation materials used in external thermal insulation composite systems (ETICS/WDVS)
Installation advice:
After drilling, the drill hole must be thoroughly cleaned using a brush or compressed air. Existing plaster must not be considered a stable load-bearing base material. Therefore, a greater drilling depth and a correspondingly longer dowel must be selected when installing through old plaster.